UL 10198
UL 1007 |
UL 1011 |
UL 1015 |
UL 1017 |
UL 1019 |
UL 1020 |
UL 1028 |
UL 1061 |
UL 1283 |
UL 1284 |
UL 1569 |
UL 10070 |
UL 2464 |
UL 2468 |
UL 3199 |
UL 3286 |
UL 3312 |
UL 3347 |
UL 3348 |
UL 3433 |
UL 3474
HUAHAO-- CABLE E231903 --- LL217627
UL 10198
1.Rated temperature:105ºC2.Rated voltage::300V
3.According to:UL subject 758,UL1581 CSA22.2 NO.210.2
4.Stranded,tinned or bare copper conductor 30-4/0AWG
5.Polyvinyl Chloride Insulated Wire
6.Passes UL VW-1 & CSA FT1 Vertical
7.Uniform insulation thickness of wire to ensure easy stripping and
cutting.
8.Environmental testing pass ROHS
9.Use for general electric equipment internal wiring.
Item | Gauge | Conductor Area | Conductor Frame | conductor outer diameter |
insulation thickness |
wire O.D | Max Cond. resistance |
|
No. | (AWG) | (mm2) | wire core qty | wire diameter | (mm) | (mm) | (mm) | (Ω/km) |
1 | 30 | 0.057 | 7 | 0.100 | 0.30 | 0.38 | 1.1 | 354 |
2 | 28 | 0.091 | 7 | 0.127 | 0.38 | 0.38 | 1.15 | 223 |
3 | 26 | 0.145 | 7 | 0.160 | 0.48 | 0.38 | 1.20 | 139.00 |
4 | 24 | 0.228 | 11 | 0.160 | 0.61 | 0.38 | 1.40 | 88.90 |
5 | 22 | 0.352 | 17 | 0.160 | 0.76 | 0.38 | 1.55 | 57.50 |
6 | 20 | 0.538 | 21 | 0.178 | 0.94 | 0.38 | 1.75 | 34.60 |
7 | 18 | 0.835 | 16 | 0.254 | 1.16 | 0.38 | 2.00 | 23.30 |
8 | 16 | 1.357 | 26 | 0.254 | 1.49 | 0.38 | 2.30 | 15.10 |
9 | 14 | 2.140 | 41 | 0.254 | 1.87 | 0.51 | 3.00 | 15.10 |
10 | 12 | 3.392 | 65 | 0.254 | 2.36 | 0.51 | 3.50 | 9.20 |
11 | 10 | 5.644 | 105 | 0.254 | 3.00 | 0.51 | 4.20 | 5.40 |
12 | 8 | 8.924 | 119 | 0.300 | 4.25 | 0.76 | 6.00 | 4.10 |
13 | 6 | 14.299 | 266 | 0.254 | 5.41 | 0.76 | 7.20 | 2.42 |
14 | 4 | 22.578 | 420 | 0.254 | 6.80 | 0.76 | 8.50 | 0.937 |
15 | 2 | 35.462 | 266 | 0.400 | 8.56 | 0.76 | 10.50 | 0.595 |
16 | 1 | 44.394 | 333 | 0.400 | 9.60 | 1.02 | 12.00 | 0.472 |
17 | 1/0 | 55.726 | 418 | 0.400 | 10.77 | 1.02 | 13.2 | 0.374 |
18 | 2/0 | 71.191 | 534 | 0.400 | 12.19 | 1.27 | 15.1 | 0.30 |