UL 3266
HUAHAO-- CABLE E231903 AWM
UL 3266
1.Rated temperature:125ºC2.Rated voltage:300V
3.According to:UL subject 758,UL1581,UL62
4.Solid or Stranded,tinned or bare copper conductor 32-10AWG
5.XLPE Insulation
6.Passes UL VW-1 & CSA FT1 Vertical flame test
7.Uniform insulation thickness of wire to ensure easy stripping and cutting.
8.Environmental testing pass ROHS
9.Use for general electric equipment internal wiring.
Item | Gauge | Conductor Area | Conductor Frame | conductor outer diameter |
insulation thickness |
wire O.D | Max Cond. resistance |
|
No. | (AWG) | (mm2) | wire core qty | wire diameter | (mm) | (mm) | (mm) | (Ω/km) |
1 | 30 | 0.057 | 7 | 0.10 | 0.30 | 0.38 | 1.1 | 354 |
2 | 28 | 0.091 | 7 | 0.13 | 0.38 | 0.38 | 1.15 | 223 |
3 | 26 | 0.145 | 7 | 0.160 | 0.48 | 0.38 | 1.20 | 139.00 |
4 | 24 | 0.228 | 11 | 0.160 | 0.61 | 0.38 | 1.4 | 88.90 |
5 | 22 | 0.352 | 17 | 0.160 | 0.76 | 0.38 | 1.55 | 57.50 |
6 | 20 | 0.538 | 21 | 0.178 | 0.94 | 0.38 | 1.75 | 34.60 |
7 | 18 | 0.835 | 16 | 0.254 | 1.16 | 0.38 | 2.1 | 23.30 |
8 | 16 | 1.357 | 26 | 0.254 | 1.49 | 0.38 | 2.3 | 17.40 |
9 | 14 | 2.140 | 41 | 0.254 | 1.87 | 0.38 | 2.70 | 15.10 |
10 | 12 | 3.392 | 65 | 0.254 | 2.36 | 0.38 | 3.20 | 9.20 |
11 | 10 | 5.644 | 105 | 0.254 | 3.00 | 0.38 | 4.25 | 5.40 |